FLOW METERS LIQUID FOOD
E200 MAGNETIC SERIES – Diam. 25- 40- 50- 80- 100 mm

200C MAGNETIC LITER COUNTER – FLOW METER
-Average accuracy from 20% to 100% of the range 0.3%
-Stainless steel flange, input output terminal or DIN
-Material in contact with the liquid, stainless steel and Teflon.
-Resolution per LITER.
-LCD display indicating: 6 large digits litres, time, preselection, liquid temperature, instant flow rate.
-Watertight stainless steel box with power switch and reset button.
-Additional LCD display to indicate the flow rate Hl/h.
-Mounted on stainless steel trolley.

E-200C-P
MAGNETIC LITER COUNTER – FLOW METER
Preselection with Pump Block
-Average accuracy from 20% to 100% of the range 0.3%
-Stainless steel flange, input output Terminal 50
-Material in contact with the liquid, stainless steel and Teflon
-Resoluon per LITER.
-LCD display indicating: 6 large digits litres, time, preselection, liquid temperature, instant flow rate.
-Watertight stainless steel box with power switch and reset button.
-Additional LCD display to indicate the flow rate Hl/h.
-Mounted on stainless steel trolley.
-Dosage preselection with automatic pump block.

E-200C-P-v MAGNETIC LITER COUNTER – FLOW METER
Preselection with pump block and motorized valve
-Average accuracy from 20% to 100% of the range 0.3%
-Stainless steel flange, input output Terminal 50
-Material in contact with the liquid, stainless steel and Teflon
-Resolution per LITER.
-LCD display indicating: 6 large digits litres, time, preselection, liquid temperature, instantaneous flow rate.
-Watertight stainless steel box with power switch and reset buon.
-Additional LCD display to indicate the flow rate Hl/h.
-Mounted on stainless steel trolley.
-Dosage preselection with automatic pump stop when quantity is reached
-Electric motorized flow blocking valve with delayed opening and closing system.
E 50 SERIE – Diam. ¾” – 1”- 1” ½- 2”

E-50 – ¾” STAINLESS STEEL VOLUMETRIC LITER METER
Liter counter enrely in AISI 304 stainless steel
-Rotang piston operaon in PTEFE
-HALL EFFECT double magnec transducer
-Double open collector separate pulse output 2 pulses per revoluon approximately 2cl to be corrected.
-Temperature sensor.
-Min. flow rate 1 l/min. – max 40 l/m
-Power supply 5 to 12 Vdc – 2 signal outputs
CLD2 LIQUID CONTROL MODULE
-Full programmable management for pump control (start-stop-reset) single or repeated dosing preselecon.
-LCD display indicating: 6 large digits litres, time, preselection, liquid temperature, instant flow rate. Liters
day, week, month, year. Time given.
-SINGLE or REPEATED preselection with automatic flow blocking via solenoid valve.
-Correction of input data, with programmable system

E-50C GROUP FLOW METER WITH PUMP AND DOSAGE PRESELECTION
-Stainless steel liter counter
-Average accuracy 0.2%
-Stainless steel GAS connecon
-Material in contact with the liquid, stainless steel and Teflon
-Resoluon to the CENTILITER.
-LCD display indicating: 6 large digits litres, time, preselection, liquid temperature, instant flow rate. Liters
day, Memory week, month, year..
-SINGLE or REPEATED preselection with automatic flow blocking via solenoid valve.
-Mounted on stainless steel trolley.
.
E 100 – Diam. 80- 100 mm

MAGNETIC FLOW METER
-Average accuracy from 20% to 100% of the range 0.3%
-Stainless steel flange, input output Terminal 50
-Material in contact with the liquid, stainless steel and Teflon
-Resolution per LITER.
-LCD display indicating: 6 large digits litres, time, preselection, liquid temperature, instant flow rate.
-Stainless steel cabinet with wheels.